Fix PF electrical accounting for Ohmic heating - #4664
grmtrkngtn wants to merge 1 commit into
Conversation
Codecov Report✅ All modified and coverable lines are covered by tests. Additional details and impacted files@@ Coverage Diff @@
## main #4664 +/- ##
=======================================
Coverage 49.73% 49.73%
=======================================
Files 151 151
Lines 30297 30297
=======================================
Hits 15069 15069
Misses 15228 15228 ☔ View full report in Codecov by Harness. 🚀 New features to boost your workflow:
|
| 1.0e0 / self.data.pf_coil.etapsu - 1.0e0 | ||
| # PF wall-plug power required for ohmic heating (MW) | ||
| wall_plug_ohmicmw = ( | ||
| self.data.physics.p_plasma_ohmic_mw / self.data.pf_coil.etapsu |
There was a problem hiding this comment.
I can be very misinformed, but why does electrical losses in the PF coil depend linearly on the plasma resistivity?
There was a problem hiding this comment.
This term is intended to represent the power-supply loss associated with transferring the ohmic heating power to the plasma, rather than a resistive loss in the PF coils themselves.
Since the plasma ohmic heating is
P_ohmic = V_loop * I_p = I_p^2 * R_plasma
and therefore depends on the plasma resistance, a fixed power-supply efficiency gives a loss
P_ohmic * (1/η_psu − 1)
The PF coil/busbar losses are accounted for separately in pfpowermw.
Description
The PF electrical demand previously included only the power-supply loss associated with ohmic heating, while the ohmic power itself was still added to the plasma thermal balance. This caused the whole-plant power balance to gain an amount exactly equal to p_plasma_ohmic_mw.
The fix accounts for the full wall-plug power required to supply ohmic heating, while only the PF supply losses contribute to secondary heat.
See #4419
************************ Power balance for power plant *************************
IN
Fusion power (MW) (p_fusion_total_mw) 1.67020126538901764e+03 OP
Energy multiplication in blanket and shield (MW) (p_blkt_multiplication_mw) 2.47869045393520537e+02 OP
TOTAL (MW) (p_nuclear_total_mw) 1.91807031078253817e+03 OP
OUT
Net electric (MW) (p_plant_electric_net_mw) 3.50000000004303502e+02 OP
Heat rejected by main power conversion circuit (MW) (p_turbine_loss_mw) 1.36108730187131050e+03 OP
Heat rejected by other circuits (secondary heat) (MW) (p_plant_secondary_heat_mw) 2.06983008906924198e+02 OP
TOTAL (MW) (p_plant_out_mw) 1.91807031078253817e+03 OP
Power plant overall imbalance (MW) (p_plant_imbalance_mw) 0.00000000000000000e+00 OP
We can see the power imabalance is correct now